Pressure Drop/ Flowrate Calculator
Input the data for the following (input only numbers):
(If the Darcy Friction factor is known, replace the value of 'e' with 'f num' where 'num' is the friction factor.)
Diameter (meters): Pipe Roughness (e) (meters):
Elevation Change (meters): Pipe Length (meters):
Fluid Viscosity (kg/(m*s)): Fluid Density (kg/m^3):
Tolerance (no units): Volumetric Flow Rate (Q) (m^3/s):
  This field is for K Losses (minor losses) due to geometry. You can enter the value directly in the
  K value window or use the calculator to add up K values if there is more than one.
  Add up K values K Value:
  If the Flow Rate (Q) is unknown but the pressure drop is, fill in this information:
  Total Pressure Drop (kPa) Qstep Qtol kPa/m
  Be careful with these
  values, or the system
  may not converge.
  Enter any work done BY the system (kW): (Work done ON the system is negative)
(This may make it more difficult to converge on Q)
Reynolds Number Darcy Friction Factor
Iterations used to find f Pressure Drop Per Length kPa/m
Total Pressure Drop kPa Volumetric Flow Rate (Q) m^3/s
By Paul Seamons